SDM-AO4 Four Channel Analog
Output Module
Revision: 4/09
12V
C1
C2
C3
AO1
AO2
AO3
A04
SDM-AO4
4 CHANNEL ANALOG OUTPUT
MADE IN USA
SN: 2270
Copyright © 1986-2009
Campbell Scientific, Inc.
Vue de la page 0
1 2 3 4 5 6 ... 17 18

Résumé du contenu

Page 1 - Output Module

SDM-AO4 Four Channel AnalogOutput ModuleRevision: 4/0912VC1C2C3AO1AO2AO3A04SDM-AO44 CHANNEL ANALOG OUTPUTMADE IN USASN: 2270Copyright © 1986-2009Camp

Page 2 - Warranty and Assistance

SDM-AO4 Four Channel Analog Output 6. Programming This section is for users who write their own datalogger programs. A datalogger program can be gen

Page 3 - SDM-AO4 Table of Contents

SDM-AO4 Four Channel Analog Output SDMAddress: The SDMAddress parameter defines the address of the SDM-AO4 to which a voltage should be applied. Vali

Page 4

SDM-AO4 Four Channel Analog Output Equation for CR5000: bit_rate=INT(k*20)*Resolution Where: k= the value entered in BitPeriod Resolution=50 nsec. 6.

Page 5 - 3. Power Supply

SDM-AO4 Four Channel Analog Output 6.3.1 CR5000 Program Example Although this program is for a CR5000 datalogger, programming for other CRBasic datal

Page 6 - 4. Physical Connections

SDM-AO4 Four Channel Analog Output 6.3.2 CR10X Program Example Although this program is for a CR10X, programming for other Edlog dataloggers is simi

Page 7 - 5. Addressing

SDM-AO4 Four Channel Analog Output 5: If time is (P92) 1: 0 Minutes (Seconds --) into a 2: 1 Interval (same units as above) 3: 10 S

Page 8

SDM-AO4 Four Channel Analog Output 12 16: Z=X+F (P34) ; Add 360 to the current reading 1: 9 X Loc [ WD_0_540 ] ; otherwise, the current r

Page 10 - 6. Programming

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Page 11 - 6.1.2 SDMSpeed Instruction

Warranty and Assistance The SDM-AO4 FOUR CHANNEL ANALOG OUTPUT MODULE is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials a

Page 12 - 6.3 Programming Examples

SDM-AO4 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab f

Page 14 - 6.3.2 CR10X Program Example

SDM-AO4 Four Channel Analog Output 1. Function The SDM-AO4 is designed to output four continuous voltages at levels set by a Campbell Scientific data

Page 15

SDM-AO4 Four Channel Analog Output 4. Physical Connections Figure 1 shows the front panel of the SDM-AO4. The terminal block on the left is used for

Page 16

SDM-AO4 Four Channel Analog Output FIGURE 1. Front Panel of the SDM-AO4 TABLE 1. Description of Terminal Block Connections Datalogger Connections 1

Page 17

SDM-AO4 Four Channel Analog Output The SDM-AO4 has sixteen possible addresses, as shown in Table 2. The address for an SDM-AO4 is hardware selectable

Page 18

SDM-AO4 Four Channel Analog Output FIGURE 2. Locational Diagram for the Address Jumpers. 5