INST
ALLATION
GUIDE
Solar1000
Solar Monitoring Station
Preliminary: 
C o p y r i g h t © 2 0 12
C a m p b e l l S c i e n t i f i c , I n c .
Vue de la page 0
1 2 3 4 5 6 ... 64 65

Résumé du contenu

Page 1 - ALLATION

INSTALLATION GUIDE Solar1000 Solar Monitoring Station Preliminary:  C o p y r i g h t © 2 0 12 C a m p b e l l S c i e n t i f i c , I n

Page 2 - Warranty

CM106 Tripod 1.5.2 Mast The CM106 includes a mast extension that can be fully extended for a 10 ft (3m) height, or partially extended for a 7 ft (2.1

Page 3 - Assistance

CM106 Tripod (6) Bolts Tab Mast FIGURE 1.5-4. Mast Attachment to Tripod Base Loosen the nine bolts shown in Figure 1.5-4. Slide the mast into the tr

Page 4 - About the Solar1000 Manual

CM106 Tripod 1.5.3 Installing the Optional Guy Kit PN 27117 CM106 Guy Kit can be ordered separately for areas that experience high wind speeds (Sect

Page 5 - 1. CM106 Tripod

CM106 Tripod CaseTurnbuckleWedgePhillips Screw FIGURE 1.5-6. Leg Attachment 9

Page 6 - 1.2. Specifications

CM106 Tripod 1.5.4 Staking the Tripod Feet Six stakes are provided for securing the tripod feet to the ground. Drive two stakes through holes in eac

Page 7 - 1.4 Tripod Components

CM106 Tripod 1.5.5 Tripod Grounding Place the clamp over the ground rod and drive the rod (close to the center of the tripod) using a sledge hammer o

Page 8 - 1.5. Tripod Installation

CM106 Tripod Strip 1/2” of insulation from the ends of the green 12 AWG wire. Attach one end of the wire to the tripod ground lug, and the other end

Page 9

CM106 Tripod 1.5.6 Crossarm Attachment Attach the CM202 (2 ft, 0.6m), CM204 (4 ft, 1.2m), or CM206 (6 ft, 1.8m) crossarm to the tripod mast as shown

Page 10 - 1.5.2 Mast

CM106 Tripod Install the U-bolts, flat washers, lock washers, and nuts. Tighten the nuts until the lock washers are compressed. Route the 14 AWG wire

Page 11

CM106 Tripod Remove the washers, nuts and U-bolt from the U-bolt bracket. Install the bracket as shown in Figure 1.5-12 (top). Tighten the nuts on the

Page 12

Warranty “PRODUCTS MANUFACTURED BY CAMPBELL SCIENTIFIC, INC. are warranted by Campbell Scientific, Inc. (“Campbell”) to be free from defects in materi

Page 13

CM106 Tripod 1.6. Mounting Brackets Mounting brackets covered in this section have U-bolts that attach to vertical and/or horizontal pipes with the f

Page 14

17 2.1 UT10 Specifications Required Concrete Pad Dimensions (see note 1): 24 x 24 x 24 in. (61 x 61 x 61 cm) Crossarm Height (attached to mast) St

Page 15 - 1.5.5 Tripod Grounding

2.2 UT10 Tower Installation The UT10 10-ft tower provides a support structure for mounting the weather station components. Figure 2.2-1 shows a typi

Page 16

Section 2. UT10 Tower Installation FIGURE 2.2-1. UT10 Weather Station UT10(3) Sleeves (4) Anchor bolts Concrete foundation FIGURE 2.2-2. UT10 Towe

Page 17 - 1.5.7 Enclosure Attachment

Section 2. UT10 Tower Installation FIGURE 2.2-3. Concrete Foundation and Anchor Bolts 2.2.2 Tower Installation 1. Install the mast as shown in Fi

Page 18

Section 2. UT10 Tower Installation 3/4" Nipple Bell Reducer Bolts to secure mast FIGURE 2.2-4. UT10 Mast 2.2.3 UT10 Tower Grounding 1. Drive

Page 19

Section 2. UT10 Tower Installation 4 AWG Wire Ground Rod 12 AWG Wire FIGURE 2.1-5. Tower Grounding 2.3 Crossarm Mounting General orientation of th

Page 20 - 1.6. Mounting Brackets

Section 2. UT10 Tower Installation FIGURE 2.2-2. CM210 crossarm-to-pole bracket (top) is included with the crossarm for attaching the crossarm to

Page 21 - Section 2. UT10

2.4 Enclosure Installation All instrumentation (datalogger, power supply, and communication peripherals) are mounted in the enclosure. A PVC bulkhead

Page 22 - 2.2 UT10 Tower Installation

Section 2. UT10 Tower Installation The default configuration is for attaching to a UT10 tower (i.e., D = 10.25”). To attach to a UT20 or UT30 tower,

Page 23

Assistance Products may not be returned without prior authorization. The following contact information is for US and International customers residing

Page 24 - 2.2.2 Tower Installation

3. HMP60 Temperature and Relative Humidity Probe 3.1. General The HMP60 Temperature and Relative Humidity probe contains a Platinum Resistance Temper

Page 25 - 2.2.3 UT10 Tower Grounding

HMP60 Temperature and Relative Humidity Probe 3.2.1 Temperature Sensor Sensor: 1000 Ω PRT, DIN 43760B Temperature Measurement Range: -40° to +60°C

Page 26 - 2.3 Crossarm Mounting

HMP60 Temperature and Relative Humidity Probe The UT6P 6-plate Radiation Shield mounts to a UT10, UT20, or UT30 tower with the UT018 horizontal mounti

Page 27

4. Met One 034B Windset 4.1. General The 034B Windset is used to measure horizontal wind speed and direction. Wind speed is measured with a three cu

Page 28 - 2.4 Enclosure Installation

Met One 034B Windset Wind Direction Measurement Range: 0 to 360° Threshold: 0.4 m s-1 (0.9 mph) Accuracy: ±4° Resolution: 0.5° Potentiometer Resis

Page 29

Met One 034B Windset The set screw holes must be covered with the labels to prevent corrosion and assure the warranty. CAUTION Mount the CM200-series

Page 30 - Humidity Probe

Met One 034B Windset CM220 CM200 Series Crossarm FIGURE 4-2. CM200 Series Crossarm with CM220 Right Angle Mounting Bracket Attach the sensor cable t

Page 31 - 3.3. Installation

5. TE525 Tipping Bucket Rain Gage 5.1. General Description The TE525 is an adaptation of the standard Weather Bureau tipping bucket rain gage. Outpu

Page 32

TE525 Tipping Bucket Rain Gage Signal Output: Momentary switch closure activated by tipping bucket mechanism. Switch closure is approximately 135 m

Page 33 - 4. Met One 034B Windset

TE525 Tipping Bucket Rain Gage The rain gage should be placed away from objects that obstruct the wind. The distance should be 2 to 4 times the heigh

Page 34 - 4.3. Installation

1 About the Solar1000 Manual This manual is a compilation of the instruction manuals for the CM106 tripod,UT10 tower, HMP60 probe, 034B windset, TE525

Page 35 - Set screw holes

6. LP02 Pyranometer 6.1. General Description This manual provides information for interfacing Hukseflux’s LP02 Pyranometer to various models of Campb

Page 36 - 4.4. Wiring

LP02 Pyranometer Spectral selectivity +/- 5% (305 to 2000 nm) Temperature response (within an interval of 50°C) within 6% (-10 to +40°C) Tilt respon

Page 37 - 5.2. Specifications

LP02 Pyranometer The sensor should be mounted with the cable pointing towards the nearest magnetic pole, e.g., in the Northern Hemisphere point the ca

Page 38 - 5.3. Installation

7. CMP6-L, CMP11-L, and CMP21-L Pyranometers 6.1. Introduction CMP-series pyranometers are designed for continuous outdoor monitoring of solar radiat

Page 39 - 5.3.2 Mounting

CMP6-L, CMP11-L, and CMP21-L Pyranometers 7.3.1 Ships With (2) Bolts for mounting from original mfg (1) Instruction Manual from original mfg (1) Su

Page 40 - 6. LP02 Pyranometer

CMP6-L, CMP11-L, and CMP21-L Pyranometers 7.4.2 Mounting See Section 7.6.1, Mounting to a Tripod Tower for more information. FIGURE 7-1. Pyranomete

Page 41 - 6.3. Installation

CMP6-L, CMP11-L, and CMP21-L Pyranometers FIGURE 7-3. Two views of a pyranometer mounted at an angle for the Northern Hemisphere FIGURE 7-4.

Page 42

CMP6-L, CMP11-L, and CMP21-L Pyranometers 7.5 Specifications 7.5.1 Pyranometers TABLE 7-1. CMP-series Specifications Specification CMP6 CMP11 CMP

Page 43 - Pyranometers

CMP6-L, CMP11-L, and CMP21-L Pyranometers FIGURE 7-6. Dimensions of the CMP6, CMP11, and CMP21 7.5.2 CVF3 Ventilation Unit Compatible Pyanometers:

Page 44 - 7.4. Quick Start

CMP6-L, CMP11-L, and CMP21-L Pyranometers 7.6. Installation 7.6.1 Mounting to a Tripod or Tower Tools required for installation on a tripod or tower

Page 45 - 7.4.2 Mounting

1. CM106 Tripod 1.1. General The CM106 is a general purpose tripod that can be used for mounting sensors, solar panels, antennas, and instrument encl

Page 46

CMP6-L, CMP11-L, and CMP21-L Pyranometers Second 1.5” u-bolt 40 First 1.5”u-boltFIGURE 7-9. CM245 bracket with 1.5” u-bolts positioned to

Page 47 - 7.5 Specifications

CMP6-L, CMP11-L, and CMP21-L Pyranometers FIGURE 7-10 Exploded view of the pyranometer mounting 7.6.2 Wiring Short Cut users should wire the sensor

Page 48 - <1 W•m

CMP6-L, CMP11-L, and CMP21-L Pyranometers 7.6.2.1 CMP6, CMP11, and CMP21 Thermopile Schematic A schematic diagram of a CMP6, CMP11, or CMP21 thermopi

Page 49 - 7.6. Installation

CMP6-L, CMP11-L, and CMP21-L Pyranometers TABLE 7-3. CMP6 and CMP11 Single-Ended Connections to Campbell Scientific Dataloggers Color Descriptio

Page 50

CMP6-L, CMP11-L, and CMP21-L Pyranometers TABLE 7-5. CMP21 Single-Ended Connections to Campbell Scientific Dataloggers Wire Color Wire Label/ D

Page 51 - 7.6.2 Wiring

Appendix A. Cut SheetsA-1

Page 52

PROGRAM EXECUTION RATE10 ms to one day @ 10 ms incrementsANALOG INPUTS (SE1-SE16 or DIFF1-DIFF8)8 differential (DF) or 16 single-ended (SE) individual

Page 53 - 7.6.2.3 CMP21 Wiring

CH100 and PS10012 Vdc Regulator and Power Supply Speci cations* Output Voltage: 12 Vdc Nominal Capacity: 7 Amp hours Input Voltage (CHG terminals)

Page 54

CHARGE - CHARGE Terminals (AC or DC Source) AC: 18 to 24 V RMS with 1.2 A RMS maximum DC: 16 to 40 Vdc with 1.1 A DC maximum S

Page 55 - Appendix A. Cut Sheets

CM106Instrumentation TripodA CM106 with the optional guy kit and an enclosure mounted to the leg base.Speci cations Measurement Height Upper Mast Re

Page 56 - CR1000 Speci cations

CM106 Tripod 1.2. Specifications Measurement Height Upper Mast Retracted: 7 ft (2.1 m) Upper Mast Extended: 10 ft (3 m) Vertical Load Limit:

Page 57 - CH100 and PS100

BP8484 Ah Rechargeable BatteryThe BP84 bracket is mounted inside an ENC16/18 with a sideplate (option -SB) and two vertical cable conduits (option -VC

Page 58 - CH200 and PS200

Required Concrete Pad Dimensions (see note 2): 24 x 24 x 24 in. (61 x 61 x 61 cm) Crossarm Height (attached to mast) Standard: 10 ft (3 m)

Page 59 - Speci cations

NL115Ethernet Interface and CompactFlash® ModuleSpeci cations Compliance: CE Compliant Power Requirements: 12 V supplied through the data- log

Page 60 - 84 Ah Rechargeable Battery

Copyright © 2009, 2012Campbell Scientifi c, Inc.Printed March 2012Speci cations Power Requirements: 12 V supplied through the data- logger’s pe

Page 61 - UT10 Speci cations

RavenXT-SeriesSierra Wireless Airlink Digital Cellular ModemsSpeci cationsRavenXTV RavenXTGTechnology CDMA 1xRTT, EVDO Rev. A, CDMA IS-95, dual bandG

Page 62

CM245 and CVF3Mounts for CMP-Series PyranometersCM245 Adjustable Angle, Mounting Stand Compatible Pipes: 1 to 2.1 in. outer diameterCVF3 Heater/Vent

Page 63 - 10baseT Ethernet Module

CM106 Tripod 1.4 Tripod Components Figure 1.4-1 shows the tripod components. The tripod base is packaged with the mast, ground rod, lightning rod an

Page 64 - RavenXT-Series

CM106 Tripod 1.5. Tripod Installation 1.5.1 Tripod Base Tripod installation near power lines is dangerous. The minimum safe recommended distance fr

Page 65 - CM245 and CVF3

CM106 Tripod mount to one of the three leg mount positions on the tripod, facing the desired direction. The tripod is typically plumbed after the mast

Commentaires sur ces manuels

Pas de commentaire