Page 1 - INSTRUCTION MANUAL

INSTRUCTION MANUALTDRSDK SoftwareDevelopment Kit for TDR1008/05Copyright (c) 2005Campbell Scientific, Inc.

Page 2

TDRSDK Software Development Kit for TDR100 6 11. SetAvgSetting Allows calling application to set the number of waveforms to be averaged for final wave

Page 3 - TDRSDK Table of Contents

TDRSDK Software Development Kit for TDR100 7 15. SetProbeLgtSetting Allows calling application to set the TDR100 probe rod length. When transaction i

Page 4

TDRSDK Software Development Kit for TDR100 8 3.4 Commands to execute TDR100 measurements and to retrieve data When a ‘request’ command is issued, Cal

Page 5 - 1. Overview

TDRSDK Software Development Kit for TDR100 9 23. GetCalVoltage Allows calling application to get TDR100 calibration voltage value stored in DLL. This

Page 6 - 3. TDR100 Command Set

TDRSDK Software Development Kit for TDR100 10 29. GetDeriWF Allows calling application to get a single TDR100 derivative waveform data point from an a

Page 7

TDRSDK Software Development Kit for TDR100 11 error occurred, La/L corrected for probe offset will be written to the DLL and can be retrieved using th

Page 8

TDRSDK Software Development Kit for TDR100 12 36. ReqWFnocal Allows calling application to request that the TDR100 acquire a new waveform without perf

Page 9

TDRSDK Software Development Kit for TDR100 13 43. GetVariables Allows calling application to get TDR100 values from algorithms that are stored in DLL.

Page 10

TDRSDK Software Development Kit for TDR100 14 46. AcqWFnocal Allows calling application to initiate the acquisition of a new waveform without first do

Page 11

TDRSDK Software Development Kit for TDR100 15 4. Sample Programs Directory example applications contain four subdirectories with examples in the four

Page 13

TDRSDK Software Development Kit for TDR100 16 This is a blank page.

Page 14

A-1 Appendix A. TDR100 Command Protocol :XXXX ffffffffHLcr Type 1 commands to set a variable (space between command and value) :XXXXHLcr Type 2 &am

Page 15

Appendix A. TDR100 Command Protocol A-2 Type 2 Commands (Gets Values) CMD HL Results :DUMP 36 Get Vp, Average, Points, Distance, Window Length, Pro

Page 16

B-1 Appendix B. TDR100 Response Protocol |S| quoted data |E| S Start Character 0x3A : (colon) E End Character 0x0D (carriage return) “ Quote Charac

Page 17

Appendix B. TDR100 Response Protocol B-2 Error Response |!|NN| ! ASCII ‘!’ to indicate an Error Packet NN Error Numbers in ASCII ‘01’ Bad Chec

Page 18

Appendix B. TDR100 Response Protocol B-3 Acknowledge Response (Response to Type 1 and Type 3 Commands) |$|CCCC| $ ASCII ‘$’ to indicate Acknowledg

Page 19 - 4. Sample Programs

Appendix B. TDR100 Response Protocol B-4 This is a blank page.

Page 20 - This is a blank page

This is a blank page.

Page 21 - Protocol

Campbell Scientific CompaniesCampbell Scientific, Inc. (CSI)815 West 1800 NorthLogan, Utah 84321UNITED [email protected]

Page 22

i TDRSDK Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab

Page 24 - Error Response

1 TDRSDK Software Development Kit for TDR100 1. Overview 1.1 Purpose of TDRSDK TDR100 Software Development Kit, TDRSDK, allows users to create custo

Page 25

TDRSDK Software Development Kit for TDR100 2 2. TDRSDK Description 2.1 Description of TDRCOM.DLL TDRCOM.DLL is a dynamically linked library, DLL, co

Page 26

TDRSDK Software Development Kit for TDR100 3 3.1 Commands for error codes, serial port control, call-back and state machine queries 1. ReadErrorCode

Page 27

TDRSDK Software Development Kit for TDR100 4 Parameters: CBfunc: Pointer to procedure that will be called (if required), upon receipt of a TDR100 com

Page 28

TDRSDK Software Development Kit for TDR100 5 3.2 Commands to retrieve TDR100 waveform parameter values The waveform parameter values are (1) relative