Appendix B. Example Programs
B.2 Control Port Example Program
The following CR5000 program uses control ports to measure three 014A wind
speed sensor. The program measures them every second and stores the mean
wind speed (in m s
–1
) every 15 seconds.
'CR5000 Series Datalogger
'Wind Speed using TimerIO Instruction
'Declare Variables and Units
Public J, WindSpeed(3)
'Define Data Tables
DataTable(Test,1,-1)
DataInterval(0,15,Sec,10)
Average(3,WindSpeed(),IEEE4,False)
EndTable
'Define Subroutines
'Sub
'Enter Sub instructions here
'EndSub
'Main Program
BeginProg
Scan (1,Sec,0,0)
'Measure the WindSpeed Profile 014A, 3 anemometers connected to C4, C5, C6 ports
TimerIO (WindSpeed(1),11000111,00222000,100,0) 'Frequency on falling edge
'Convert measurement to m/s
For j = 1 to 3
WindSpeed(j) = 0.447 + WindSpeed(j)/1.25
Next j
CallTable Test
Next Scan
End Prog