Campbell-scientific CR1000 Measurement and Control System Manuel d'utilisateur Page 179

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 588
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 178
Section 7. Installation
179
Table 26. SDI12Recorder() Commands
SDIRecorder() Instruction
SDICommand Entry
Actions Internal to
CR1000 and Sensor
2
Use variable replacement in program to use same instance of SDI12Recorder() as issued aCV!
(see the CRBasic example Using SDI12Recorder() C Command
).
Alternate Start Measurement Command (Cv)
The SDIRecorder() aCv (not C!) command facilitates using the SDI-12 standard
Start Concurrent command (aCv!) without the back-to-back measurement
sequence normal to the CR1000 implementation of aCv!.
Consider an application wherein four SDI-12 temperature sensors need to be near-
simultaneously measured at a 5 minute interval within a program that scans every
5 seconds. The sensors requires 95 seconds to respond with data after a
measurement request. Complicating the application is the need for minimum
power usage, so the sensors must power down after each measurement.
This application provides a focal point for considering several measurement
strategies. The simplest measurement is to issue a M! measurement command to
each sensor as follows:
Public BatteryVolt
Public Temp1, Temp2, Temp3, Temp4
BeginProg
Scan(5,Sec,0,0)
'Non-SDI-12 measurements here
SDI12Recorder(Temp1,1,0,"M!",1.0,0)
SDI12Recorder(Temp2,1,1,"M!",1.0,0)
SDI12Recorder(Temp3,1,2,"M!",1.0,0)
SDI12Recorder(Temp4,1,3,"M!",1.0,0)
NextScan
EndProg
However, the code sequence has three problems:
1. It does not allow measurement of non-SDI-12 sensors at the required
frequency.
2. It does not achieve required 5-minute sample rate because each
SDI12Recorder() instruction will take about 95 s to complete before the next
SDI12Recorder() instruction begins, resulting is a real scan rate of about 6.5
minutes.
3. There is a 95-second time skew between each sensor measurements.
Problem 1 can be remedied by putting the SDI-12 measurements in a
SlowSequence scan. Doing so allows the SDI-12 routine to run its course
without affecting measurement of other sensors, as follows:
Public BatteryVolt
Public Temp(4)
BeginProg
Vue de la page 178
1 2 ... 174 175 176 177 178 179 180 181 182 183 184 ... 587 588

Commentaires sur ces manuels

Pas de commentaire

Philips HTR5204 manuals

Owner’s manuals and user’s guides for CD players Philips HTR5204.
We providing pdf manuals Philips HTR5204 for download free by document types:






More products and manuals for CD players Philips

Models Document Type
DVDQ40/022 User Manual    Philips DVDQ40/022 User's Manual, 26 pages
AZ382/12 User Manual   Philips AZ382/12 User's Manual, 2 pages
MZ1000 User Manual   Philips MZ1000 User's Manual, 25 pages
EXP4318 User Manual      Philips EXP4318 User's Manual, 82 pages
AZT3201 User Manual      Philips AZT3201 User's Manual, 10 pages
ACT 7585 User Manual      Philips ACT 7585 User's Manual, 65 pages
AZ3012/01 User Manual    Philips AZ3012/01 User's Manual, 8 pages
eXpanium EXP212 User Manual      Philips eXpanium EXP212 User's Manual, 2 pages
AZ 1565/00 User Manual       Philips AZ 1565/00 User's Manual, 63 pages
AZT3200 User Manual     Philips AZT3202/17 User manual, 14 pages
EXP2550/58 User Manual      Philips EXP2550/58 User manual, 2 pages
EXP3360 User Manual   Philips EXP3360 User's Manual, 12 pages
AZ7681 User Manual       Philips AZ7681 User's Manual, 132 pages
EXP220/01 User Manual   Philips EXP220/01 User manual, 5 pages
PORTABLE SPORT AUDIO PSA[CD User Manual      Philips PORTABLE SPORT AUDIO PSA[CD User's Manual, 14 pages
AX5311/17 User Manual   Philips AX5311/17 User manual, 13 pages
AZ7182 User Manual   Philips AZ7182 User's Manual, 2 pages
AZ2000/01 User Manual   Philips AZ2000/01 User's Manual, 11 pages
AX5301/00C User Manual   Philips AX5301/00C User's Manual, 2 pages
AZ 1145 User Manual      Philips AZ 1145 User's Manual, 53 pages