Campbell-scientific CS431 Submersible Pressure Transducer Manuel d'utilisateur Page 1

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Campbell-scientific CS431 Submersible Pressure Transducer. Campbell Scientific CS431 Submersible Pressure Transducer User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 22
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
CS431 Submersible
Pressure Transducer
Revision: 3/09
Copyright © 2008-2009
Campbell Scientific, Inc.
Vue de la page 0
1 2 3 4 5 6 ... 21 22

Résumé du contenu

Page 1 - Pressure Transducer

CS431 SubmersiblePressure TransducerRevision: 3/09Copyright © 2008-2009Campbell Scientific, Inc.

Page 2 - Warranty and Assistance

CS431 Submersible Pressure Transducer This function is designed for the thermistor used in the CS431. It automatically selects the excitation voltage

Page 3 - CS431 Table of Contents

CS431 Submersible Pressure Transducer Public Temp(2) 'temperature, one per sensor Public L(2) 'L factor (Vo/Vr * 100), one per se

Page 4 - Figures

CS431 Submersible Pressure Transducer 5.1.1.2 Example CR1000 PROGRAM – ENHANCED CALIBRATION – Two Sensors 'Program = Sample Enhanced Program for

Page 5 - Transducer

CS431 Submersible Pressure Transducer 'Sensor 2 (typical 15 psig sensor) m2(2) = 0.000000133861 m1(2) = 0.000001790422 m0(2) = 0.192297242812

Page 6 - 3. Installation

CS431 Submersible Pressure Transducer 5.2.1 Example Edlog Programs The following two examples are for the CR10X but other Edlog dataloggers are progr

Page 7 - 4. Wiring

CS431 Submersible Pressure Transducer 5.2.1.2 Example CR10X PROGRAM – Enhanced Measurement In the following example Vr = differential voltage at dif

Page 8 - 5. Datalogger Programming

CS431 Submersible Pressure Transducer 5.2.1.3 Example CR10X PROGRAM – High Precision Measurement for 5 PSI Sensors The Standard and Enhanced Measurem

Page 9 - 5.1 CRBasic Instructions

CS431 Submersible Pressure Transducer ; L can be translated to a pressure measurement using the following formula, ; where m and b (in psi) are deter

Page 10

CS431 Submersible Pressure Transducer 7. Troubleshooting 7.1 Erratic Readings Assuming that the datalogger is working properly, the first thing to c

Page 11

CS431 Submersible Pressure Transducer The best method for minimizing ground loops is to tie all equipment (sensors, dataloggers, external power source

Page 12

Warranty and Assistance The CS431 SUBMERSIBLE PRESSURE TRANSDUCER is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in materials and w

Page 13 - 5.2 Edlog Instructions

CS431 Submersible Pressure Transducer 16

Page 14

This is a blank page.

Page 15 - 2, b1, and b0

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com info@campbells

Page 16

CS431 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for

Page 17 - 6. Maintenance

CS431 Table of Contents ii Figures 4.1. Typical Pressure Element Wiring ... 3 4-2. Typical T

Page 18 - 7. Troubleshooting

CS431 Submersible Pressure Transducer 1. General Description The CS431 PS9805 Pressure Transducer is manufactured by Instrumentation Northwest for us

Page 19

CS431 Submersible Pressure Transducer 3. Installation 3.1 Initial Inspection Upon receipt of the CS431, inspect the packaging for any signs of shipp

Page 20

CS431 Submersible Pressure Transducer 3.5 Other Installations The CS431 can be installed in any position; however, when it leaves the factory it is t

Page 21 - This is a blank page

CS431 Submersible Pressure Transducer FIGURE 4-2. Typical Temperature Element Wiring 4.2 Grounding Proper grounding is very important! CAUTION To p

Page 22

CS431 Submersible Pressure Transducer • Compute the normalized ratiometric output (L) as: L = (Vo/Vr) * 100. • Apply calibration/scaling values (fro