Campbell-scientific EnviroSCAN Sentek Water Content Profile Probe Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Instruments de mesure Campbell-scientific EnviroSCAN Sentek Water Content Profile Probe. Campbell Scientific EnviroSCAN Sentek Water Content Profile Probe User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - Content Profile Probes

EnviroSMART™ Soil WaterContent Profile ProbesRevision: 3/09Copyright © 2002-2009Campbell Scientific, Inc.EnviroSMART™, EasyAG®, and IrriMAX® are trad

Page 2 - Warranty and Assistance

EnviroSMARTTM Soil Water Content Profile Probes 8.2 Cable Installation Securely tighten the gland nut through which the cable passes into the probe c

Page 3 - Table of Contents

EnviroSMARTTM Soil Water Content Profile Probes ‘Program Control Variables Dim X ‘Definition of DataTables DataTable (ES1_SF,1,-1) Sample

Page 4 - Figures

EnviroSMARTTM Soil Water Content Profile Probes Else ‘...OR... If ES1_SF(X) < -999 Then ‘If a WC sensor fails (indicated by

Page 5

EnviroSMARTTM Soil Water Content Profile Probes ;Wiring: EnviroSMART / EasyAG 12 Volts (Pin 1) -------- CR10X 12 V ; EnviroSMART / EasyAG G

Page 6 - 5. Resolution and Accuracy

EnviroSMARTTM Soil Water Content Profile Probes 7: If (X<=>F) (P89) 1: 1 X Loc [ ES1_SF_1 ] 2: 2 <> 3: 0 F 4: 3

Page 7

EnviroSMARTTM Soil Water Content Profile Probes 17: If (X<=>F) (P89) ;If 1st sensor reading is < -9999 i.e. = -99999 1: 1 X Loc

Page 8 - 6. Specifications

EnviroSMARTTM Soil Water Content Profile Probes 28: Z=X^Y (P47) 1: 9 -- X Loc [ ES1_WC_1 ] 2: 34 Y Loc [ RecipB ] 3: 9 --

Page 9 - 8. Probe Wiring

EnviroSMARTTM Soil Water Content Profile Probes 40: Sample (P70) 1: 1 Reps 2: 26 Loc [ Irrig_mm ] ;Output Water Content Data to Storage 4

Page 10 - 9. Datalogger Programming

EnviroSMARTTM Soil Water Content Profile Probes 14 28 _________ 0 0 0 29 C 1 1 0 30 A 1 1 0 31 _________ 0 0 0 32 B 1 1 0 33 _

Page 11

Appendix A. Probe Assembly FIGURE A-1. Finished EnviroSMARTTM Assembly Figure A-1 shows a finished three-sensor probe. Your probe may require more

Page 12

Warranty and Assistance The EnviroSMART™ SOIL WATER CONTENT PROFILE PROBES are warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in mater

Page 13

Appendix A. Probe Assembly “Loosely” attach the handle to the rod with two of the large screws that came with the assembly as shown in Figure A-3. F

Page 14

Appendix A. Probe Assembly FIGURE A-7. Sensor Orientation FIGURE A-8. Sensor Ribbon Cable Determine the number and locations of sensors that are

Page 15

Appendix A. Probe Assembly FIGURE A-10. Aligning Sensor Tab with Probe Slot FIGURE A-11. Plugging in Ribbon Cable Header Advance the sensor to it

Page 16

Appendix A. Probe Assembly FIGURE A-13. Location of Addressing Jumpers FIGURE A-14. Location of Jumper 1 FIGURE A-15. Location of Jumper 2 A-5

Page 17

Appendix A. Probe Assembly FIGURE A-16. Location of Jumpers 1..16 After positioning and securing each sensor in its proper location, install the ju

Page 18 - 11. Acknowledgements

Appendix B. Normalization and Function Test Normalization is the setting of the range over which the electronics is effective. This range is bounded

Page 19 - Appendix A. Probe Assembly

Appendix B. Normalization and Function Test Start the IPConfig Utility (Intelligent Probe Utility Software, P/N SEN06025) on the PC by clicking on th

Page 20

Appendix B. Normalization and Function Test 1. Click on “Auto-detect Sensors” in the lower left corner. Wait until all sensors are auto-detected.

Page 21

Appendix B. Normalization and Function Test B.1.2 TriSCAN Normalization When normalizing TriSCAN sensors for water content, follow the procedure in

Page 22

Appendix B. Normalization and Function Test B.2 Configuration Testing FIGURE B-6. IPConfig Configuration Test Window Test the configuration by goi

Page 23

EnviroSMARTTM Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks

Page 24

Appendix B. Normalization and Function Test B-6 This is a blank page.

Page 25 - Function Test

Appendix C. Access Tube Installation The information below is a summary. Further information is provided in the Sentek Diviner2000® Installation Gui

Page 26 - B.1.1 Water Content Only

Appendix C. Access Tube Installation C.1 Standard Access Tube Installation C.1.1 Installation Tools Toolkit items Installation Toolkit No. 1 Items

Page 27

Appendix C. Access Tube Installation C.1.2 Installing the Access Tube Figure C-1. Incorrect Installation To install the access tube, follow these

Page 28 - B.1.2 TriSCAN Normalization

Appendix C. Access Tube Installation 11. Use a sledgehammer to tap the dolly until the access tube is embedded approximately 5-10 cm into the soil.

Page 29 - B.2 Configuration Testing

Appendix C. Access Tube Installation 5. Select Access Tube Cleaning Tool no. 3 — rag tool. Insert a clean cotton cloth into the eyelet and saturat

Page 30 - This is a blank page

Appendix C. Access Tube Installation 5. Wipe off excess silicon from the inside of the access tube. 6. Screw the cap back onto the top cap housing.

Page 31

Appendix C. Access Tube Installation 16. Winch the access tube carefully upward and out of the ground. 17. Remove the access tube from the extract

Page 32 - C.1.1 Installation Tools

Appendix C. Access Tube Installation C-8 This is a blank page.

Page 33

Appendix D. Site Selection Site selection is a critical process for all soil water sensors. A properly selected site will reflect changes in soil mo

Page 34

EnviroSMARTTM Table of Contents ii B. Normalization and Function Test...B-1 B.1 Normalization...

Page 35

This is a blank page.

Page 36 - C.2 Access Tube Removal

Appendix E. SDI-12 Commands The SDI-12 EnviroSMART probe interface communicates with Campbell Scientific dataloggers by way of SDI-12 protocol. A co

Page 37

This is a blank page.

Page 39 - Appendix D. Site Selection

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbel

Page 40

EnviroSMARTTM Soil Water Content Profile Probes 1. General EnviroSMARTTM probes measure a profile of volumetric soil water content. EnviroSMART prob

Page 41 - Appendix E. SDI-12 Commands

EnviroSMARTTM Soil Water Content Profile Probes 4.1 Water Content Sensor output is a dimensionless frequency (raw count) that is converted via a norm

Page 42

EnviroSMARTTM Soil Water Content Profile Probes VIC can be related directly to a site-specific soil EC through the use of Sentek’s Benchmarking Proced

Page 43

EnviroSMARTTM Soil Water Content Profile Probes 6. Specifications Feature EnviroSMARTTM SDI-12 Maximum cable length to logger or third party device 6

Page 44

EnviroSMARTTM Soil Water Content Profile Probes 7. Installation Several configurations are possible when using the EnviroSMARTTM / EasyAG® Probes wit