Campbell-scientific RAWS-F Remote Automated Weather Station for Fire W Manuel d'utilisateur Page 23

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 58
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 22
RAWS-F Remote Automated Weather Station for Fire Weather
FIGURE 4-5. 2-D WindSonic
Blue north
marker arrow
4.5.2.2 Wiring
The WindSonic4-LQ attaches to the connector labeled SDI-12; this connector
is color coded red. The sensor is internally wired from the RAWS connector
panel to the CR1000.
TABLE 4-5. SDI-12 Connector (color coded yellow)
Connector Pin Description CR1000 Terminal
A SDI-12 Signal C7
B 12 V 12V
C Power Ground G
4.5.2.3 Maintenance
There are no user-serviceable parts on the 2-D Sonic Wind Sensor. Keep the
transducer paths clear of any obstructions. When clearing the transducer paths,
do not remove the “rubber” caps on each of the transducers.
4.5.2.4 Calibration
Recalibrate the 2-D Sonic Wind Sensor annually. Obtain an RMA number
before returning this sensor to Campbell Scientific for recalibration.
15
Vue de la page 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 57 58

Commentaires sur ces manuels

Pas de commentaire