Campbell-scientific CR800 and CR850 Measurement and Control Systems Manuel d'utilisateur Page 455

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 566
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 454
Appendix A. CRBasic Programming Instructions
455
A.2.3 Final Data Storage (Output) Processing
Read More! See Data Output Processing Instructions (p. 130).
FieldNames
Immediatelyfollowsanoutputprocessinginstructiontochangedefaultfield
names.
Syntax
FieldNames("Fieldname1 : Description1, Fieldname2 :
Description2…")
A.2.3.1 Single-Source
Average
Storestheaveragevalueovertheoutputintervalforthesourcevariableoreach
elementofthearrayspecified.
Syntax
Average(Reps, Source, DataType, DisableVar)
Covariance
Calculatesthecovarianceofvaluesinanarrayovertime.
Syntax
Covariance(NumVals, Source, DataType, DisableVar, NumCov)
FFT
PerformsaFastFourierTransformonatimeseriesofmeasurementsstoredinan
array.
Syntax
FFT(Source, DataType, N, Tau, Units, Option)
Maximum
Storesthemaximumvalueovertheoutputinterval.
Syntax
Maximum(Reps, Source, DataType, DisableVar, Time)
Median
Storesthemedianofadependantvariableovertheoutputinterval.
Syntax
Median(Reps, Source, MaxN, DataType, DisableVar)
Minimum
Storestheminimumvalueovertheoutputinterval.
Syntax
Minimum(Reps, Source, DataType, DisableVar, Time)
Moment
Storesthemathematicalmomentofavalueovertheoutputinterval.
Syntax
Moment(Reps, Source, Order, DataType, DisableVar)