Section 6. Data Table Declarations and Output Processing Instructions
Maximum (Reps, Source, DataType, DisableVar, Time)
This instruction stores the Maximum value that occurs in the specified Source
variable over the output interval. Time of maximum value(s) is Optional
output information, which is selected by entering the appropriate code in the
time parameter. NANs are ignored by this output processing instruction.
Parameter
Enter
MAXIMUM PARAMETERS
Reps
Constant
The number of maximum values to determine. When repetitions are greater than 1, the source must be
an array..
Source
Variable
The name of the Variable that is the input for the instruction.
DataType
A code to select the data storage format. Read More: See Section 4.2.4.4 Data Types
Constant
Alpha Code Numeric Code Data Format
IEEE4 24 IEEE 4 byte floating point
FP2 7 Campbell Scientific 2 byte floating point
UINT2 21 2 Byte unsigned integer
Long 20 4 Byte Integer value
DisableVar
Constant,
Variable, or
A non-zero value will disable intermediate processing. Normally 0 is entered so all inputs are processed.
For example, when the disable variable is 0 the current input is not checked for a new maximum. The
maximum that is eventually stored is the maximum that occurred while the disable variable was 0.
Expression
Value Result
0 Process current input
0
Do not process current input
Time
Option to store time of Maximum. When time is output, the maximums for all reps are output first
followed by the respective times at which they occurred.
Constant
Value Result
0 Do not store time
1 Store time Time of max is stored in the NSec format.
Median
The Median instruction stores the median value over time of a variable to an
output table.
Syntax
Median(Reps, Source, MaxN, DataType, DisableVar)
Remarks
Median is an output instruction that is included within a data table declaration.
Each time the DataTable is called and the DisableVar is False, the current
Source value is stored to an array in internal memory. This array is
dimensioned with MaxN number of elements. Therefore, no more than MaxN
values are retained in memory. If MaxN + 1 number of stored values is reached
before the DataTable output is triggered, then the oldest stored value in the
array will be discarded.
When the DataTable's output condition is True, the instruction outputs the
Median of the values in memory to the DataTable, and then memory for the
instruction is cleared. If the number of values for which the median is
calculated is an even number, the two median values will be averaged.
NANs and +
INFs are considered to be the most minimum values in the
determination of the Median.
6-25
Vue de la page 208
1 2 ... 204 205 206 207 208 209 210 211 212 213 214 ... 441 442

Commentaires sur ces manuels

Pas de commentaire

Norgren F07 Series manuals

Owner’s manuals and user’s guides for Hardware Norgren F07 Series.
We providing 1 pdf manuals Norgren F07 Series for download free by document types: User Manual


Norgren F07 Series User Manual (2 pages)


Brand: Norgren | Category: Hardware | Size: 0.03 MB |

 

Table of contents





More products and manuals for Hardware Norgren

Models Document Type
F46 Series User Manual   Norgren F46 Series User Manual, 1 pages
F22 Series Datasheets User Manual   Norgren F22 Series Datasheets User Manual, 2 pages
F72C Series User Manual   Norgren F72C Series User Manual, 1 pages
F72G Series User Manual   Norgren F72G Series User Manual, 1 pages
F73G Series User Manual   Norgren F73G Series User Manual, 1 pages
F74G Series User Manual   Norgren F74G Series User Manual, 1 pages
B07 Series Datasheets User Manual   Norgren B07 Series Datasheets User Manual, 2 pages
B07 Series Installation Instructions User Manual   Norgren B07 Series Installation Instructions User Manual, 2 pages
B64G Series User Manual   Norgren B64G Series User Manual, 4 pages
B38SS Series Installation Instructions User Manual   Norgren B38SS Series Installation Instructions User Manual, 2 pages
B38SS Series Datasheets User Manual   Norgren B38SS Series Datasheets User Manual, 2 pages
B38AL Series Datasheets User Manual   Norgren B38AL Series Datasheets User Manual, 2 pages
B38AL Series Installation Instructions User Manual   Norgren B38AL Series Installation Instructions User Manual, 1 pages
Filter Contents User Manual   Norgren Filter Contents User Manual, 53 pages
B74G Series Datasheets User Manual   Norgren B74G Series Datasheets User Manual, 2 pages
B38-240-B2KA User Manual   Norgren B38-240-B2KA User Manual, 4 pages
B74G Series Installation Instructions User Manual   Norgren B74G Series Installation Instructions User Manual, 2 pages
B73G Series User Manual   Norgren B73G Series User Manual, 2 pages
B72G Series Datasheets User Manual   Norgren B72G Series Datasheets User Manual, 2 pages
B72G Series Installation Instructions User Manual   Norgren B72G Series Installation Instructions User Manual, 2 pages