Page 1 - Mobile App for

Copyright © 2012- 2014 Campbell Scientific, Inc. LoggerLink Mobile App for iOS Revision: 2/14

Page 2 - Table of Contents

datalogger's settings. When connecting to a datalogger, a clock check is sent to see if communications can be established. On the first connec

Page 3 - Requirements

Tap the config button in the upper right corner to select and configure a different table. TOC 9

Page 4 - Getting Started

Values are formatted based on type and, by default, include the units defined in the datalogger program. Tapping a settable value opens a page that a

Page 5

Field Title The name that will be displayed for the field. Field Units The measurement units that will be displayed for the field. Precision The numb

Page 6 - Connecting

Note that a red E on the Status icon indicates that the datalogger has errors. Scroll down on the Status screen to identify the error. You can press

Page 7 - Disconnecting

Started The date the currently running program was started. Signature Signature of the compiled binary data structure for the current program. This

Page 8 - Datalogger Setup—Settings

datalogger. With iTunes open and your device connected to your computer, click on the name of your device and then click Apps near the top center of

Page 9

Compile State The state of the program after the datalogger tried to compile it. Possible states are: No Program, Program Running, Compile Failed, P

Page 10 - Current

Low 12V Count The number of occurrences of the 12VLow signal being asserted. When this condition is detected, the datalogger ceases measurements and

Page 11

Card Info Card Status Reports the status of the CF card. Bytes Free The amount of space still available on the CF card. Clock Info System The local t

Page 12

Table of Contents Introduction ... 1 Requirements ...

Page 13

Historic The historic page displays data from a single datalogger table in graph or tabular form. TOC 18

Page 14

The first time you open the historic window for a datalogger, you will automatically be taken to the Historic Setup. This allows you to select the t

Page 15

On the table, the current data will be displayed in tabular format. You may sort the data by time simply by tapping the Time column heading. Histori

Page 16

Graph Symbol Color The color of the symbol used for the graph series. Graph Symbol Symbol The symbol that is used for the graph series. Collect Data

Page 17

If your device does not have email capabilities or a file-sharing application, iTunes is required to copy collected data files to your computer. Wi

Page 18

your computer, click on the name of your device and then click Apps near the top center of the window. Under File Sharing, click on LoggerLink. Und

Page 19

will show a list of installed applications that are registered to handle .dat file types. If you have a file-sharing application, such as Dropbox, t

Page 20 - Historic

location to save your data. After browsing to the desired location, press Select Folder in the browser window and your data will be copied to your c

Page 21

options to save the edited file to your iOS device (Save Local) or save the edited file to your datalogger. The Save to Datalogger option gives you

Page 22

Send File(s) Files can be sent from your device to the datalogger. Selecting this option will display a list of local files you can select to send t

Page 23 - Collect Data

Introduction Please read the End User License Agreement (EULA). LoggerLink for iOS is a simple yet powerful tool that lets you communicate directly w

Page 24

Delete File(s) After selecting files from the datalogger file list, you can delete the files from the datalogger. Get File(s) After selecting files f

Page 25

On Power-up will set this program file to run when the datalogger loses power and then powers back up. Settings The Settings page is used to view and

Page 26

Cancel Changes If unapplied changes have been made to any settings, the Cancel Changes option will be available. Cancel Changes will discard any pen

Page 27

the page that is displayed by tapping the disclosure button next to the datalogger in the list of dataloggers). Clicking the disclosure button next

Page 28

LoggerLink Settings The following settings for LoggerLink can be viewed and/or set from your device's Settings screen. Tap on LoggerLink under

Page 29

With iTunes open and your device connected to your computer, click on the name of your iOS device and then click Apps near the top center of the wind

Page 30

End User License Agreement (EULA) for Mobile Applications NOTICE OF AGREEMENT: Please carefully read this EULA. By installing or using this software,

Page 31 - Settings

LICENSE FOR USE: The Licensed Application is licensed, not sold, to you for use under the following terms and conditions: Scope: This license is lim

Page 32 - Off-line Files

software, and peripherals, that is gathered periodically to facilitate the provision of software updates, product support and other services to You (

Page 33

manner consistent with the published recommendations, including recommended system requirements. CSI disclaims all other warranties including those i

Page 34 - LoggerLink Settings

Getting Started When LoggerLink is launched, you can add new dataloggers by tapping the "+" button in the upper right corner of the screen.

Page 35

LIMITATION OF LIABILITIES: All warranties of merchantability and fitness for a particular purpose are disclaimed and excluded. Your sole and exclusiv

Page 36

country; and (ii) are not listed on any U.S. Government list of prohibited or restricted parties. THIRD PARTY BENEFICIARY: By accepting this agreemen

Page 37

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Page 38

automatically filled in to the Datalogger Setup screen. After manually filling in any additional settings, tap the Save button to add the datalogger

Page 39

Connecting To connect to a datalogger, simply tap on it in the list of dataloggers. TOC 4

Page 40

Connected After you have connected to your datalogger, a set of tabs will appear at the bottom of the screen. Tapping on these tabs will allow you t

Page 41

Datalogger Setup—Settings TCP Settings Address The TCP/IP Address of the device you will be communicating with. Port The TCP/IP Port the device is ac

Page 42

Neighbor The PakBus address of the neighbor you will go through to connect to your datalogger. A value of 0 means you will connect directly to your

Commentaires sur ces manuels

Pas de commentaire