Campbell-scientific LoggerNet-SDK Software Development Kit Manuel d'utilisateur Page 123

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 178
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 122
Section 17. CsiDatalogger Control Reference
Enumeration Name Value Description
server_failure_session 2 Indicates that the communication session with the
server failed resulting in the serverConnect
transaction failing
server_failure_unsupported 3 Indicates that the datalogger defined in the property
loggerName could not support this transaction
server_failure_security 4 Indicates that the server has security enabled and
that the serverLogonName or the
serverLogonPassword properties did not have
sufficient privileges to perform this method
server_failure_bad_host_or_port 5 Indicates that either the serverName or the
serverPort property is incorrect
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return.
Datalogger_onServerConnectStarted()
Name
onServerConnectStarted()
Description
This event gets called once a connection has been established with the
LoggerNet server using the serverConnect() method.
COM Return Values
Table of Possible Values
Code Meaning
S_OK
Success: Normal return
17-25