Résumé du contenu

Page 1 - Android

Copyright © 2012- 2014 Campbell Scientific, Inc. LoggerLink Mobile App for Android Revision: 3/14

Page 2 - Table of Contents

Name The Name used to identify this datalogger in LoggerLink. Data files collected from this datalogger will be stored in a sub-directory with this

Page 3 - Getting Started

TCP Password If you are trying to connect via TCP to a datalogger with a TCP Password enabled, you must enter the password in order for any communica

Page 4 - Datalogger Setup

Tap the icon in the upper right corner to select and configure a different table. TOC 10

Page 5 - Bluetooth Connection

Values are formatted based on type and, by default, include the units defined in the datalogger program. Touch and hold a settable value to open a pa

Page 6

Precision The number of digits of precision used. (Only displayed if the field value is floating point type.) Status The status page shows important

Page 7

TOC 13

Page 8 - Disconnecting

Program Info Current The program currently running in the datalogger. Started The date the currently running program was started. Signature Signature

Page 9 - Datalogger Setup—Settings

Datalogger Info Station Name A name assigned to this datalogger. Note that this is the station name internal to the datalogger. It is not the name

Page 10

Memory Size The total amount of SRAM in the datalogger. Memory Free The amount of unallocated memory on the CPU (SRAM). All free memory may not be

Page 11 - Current

Skipped Scans The number of skipped scans that have occurred while running the current program. Does not include scans intentionally skipped as may

Page 12

Table of Contents Introduction ... 1 Requirements ...

Page 13

Clock Info System The local time of your device the last time the datalogger clock was checked. Logger The time reported by the datalogger the last t

Page 14

The first time you open the historic window for a datalogger, you will automatically be taken to the Historic Setup. This allows you to select the t

Page 15

option for showing the legend is also available. You can tap Data Range to change the data range that will be displayed. (The default data range is

Page 16

Show Legend Determines whether a legend is shown on the graph. Data Range The range of data to be displayed in the graph and table. Field Options Fie

Page 17

files can then be viewed, emailed from your device, or opened in another application. TOC 22

Page 18

Collected data files are stored on your device in the Campbellsci/Data/name directory, where name is the name given to your datalogger when it was ad

Page 19

Files The Files page is used to view the drives on your datalogger as well as pause/resume the currently running program. You can also view and edit

Page 20 - Historic

upper right corner.) If no files are selected, you have the option to format the drive or send files to the datalogger from your device. If you hav

Page 21

Get File(s) After selecting files from the datalogger file list, you can get the files from the datalogger and store them on your device. (Retrieved

Page 22

changes to the table structure of the new program. The Run On Power-up will set this program file to run when the datalogger loses power and then po

Page 23 - Collect Data

Introduction Please read the End User License Agreement (EULA). LoggerLink for Android™ is a simple yet powerful tool that lets you communicate direc

Page 24

Disconnect When you are finished interacting with your datalogger, tap your devices’s Menu button and select Disconnect (or simply tap your device’s

Page 25

Clicking the eye icon next to a file allows you to view that file. While viewing a program file, you can edit the file and then tap the disk icon in

Page 26

with an ID greater than 3999, but will ignore devices with IDs less than 4000 that are not in their neighbor list. Settings: Prevent Sleep The Preven

Page 27

End User License Agreement (EULA) for Mobile Applications NOTICE OF AGREEMENT: Please carefully read this EULA. By installing or using this software,

Page 28

LICENSE FOR USE: The Licensed Application is licensed, not sold, to you for use under the following terms and conditions: Scope: This license is lim

Page 29 - Settings

software, and peripherals, that is gathered periodically to facilitate the provision of software updates, product support and other services to You (

Page 30 - Off-line Files

manner consistent with the published recommendations, including recommended system requirements. CSI disclaims all other warranties including those i

Page 31 - LoggerLink Settings

Licensed Application, however caused, regardless of the theory of liability (contract, tort or otherwise) and even if Campbell Scientific, Inc. has b

Page 32

TERMINATION: This license is effective until terminated by You or by Campbell Scientific, Inc. Your rights under this license will terminate automati

Page 33

Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 North Logan, Utah 84321 UNITED STATES www.campbellsci.com • info@campbe

Page 34

button, these functions can be accessed from the menu button on the right end of the action bar at the top of the LoggerLink screen. Datalogger Setup

Page 35

reachable from that IP address. Tap a datalogger in the list to have its settings automatically filled in to the Datalogger Setup screen. After man

Page 36

See the Datalogger Setup section for an explanation of each field on the Datalogger Setup screen. After you have finished setting up a datalogger, it

Page 37

Connecting To connect to a datalogger, simply tap on it in the list of dataloggers. TOC 5

Page 38

Connected After you have connected with your datalogger, a set of tabs will appear at the top of the screen. Tapping on these tabs will allow you to

Page 39

Datalogger Setup—Settings TCP Settings Address The TCP/IP Address of the device you will be communicating with. Port The TCP/IP Port the device is ac