Campbell-scientific CR3000 Micrologger Manuel d'utilisateur Page 298

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 590
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 297
Section 8. Operation
298
Table 61. Status Table Calibration Entries
Descriptions of Status Table Elements
Status Table
Element
Differential (Diff)
Single-Ended (SE)
Offset or Gain
±mV Input
Range
Integration
CalDiffOffset(10) Diff Offset 20 60-Hz Rejection
CalDiffOffset(11) Diff Offset 5000 50-Hz Rejection
CalDiffOffset(12) Diff Offset 1000 50-Hz Rejection
CalDiffOffset(13) Diff Offset 200 50-Hz Rejection
CalDiffOffset(14) Diff Offset 50 50-Hz Rejection
CalDiffOffset(15) Diff Offset 20 50-Hz Rejection
Table 62. Calibrate() Instruction Results
Descriptions of Array Elements
Array
Cal()
Element
Differential (Diff)
Single-Ended (SE) Offset or Gain
±mV Input
Range Integration
Typical Value
1 SE Offset 5000 250 ms ±25 LSB
2 Diff Offset 5000 250 ms ±25 LSB
3 Gain 5000 250 ms -1.67 mV/LSB
4 SE Offset 1000 250 ms ±25 LSB
5 Diff Offset 1000 250 ms ±25 LSB
6 Gain 1000 250 ms -0.0333 mV/LSB
7 SE Offset 200 250 ms ±30 LSB
8 Diff Offset 200 250 ms ±30 LSB
9 Gain 200 250 ms -0.00667 mV/LSB
10 SE Offset 50 250 ms ±30 LSB
11 Diff Offset 50 250 ms ±30 LSB
12 Gain 50 250 ms -0.00167 mV/LSB
13 SE Offset 20 250 ms ±35 LSB
14 Diff Offset 20 250 ms ±35 LSB
15 Gain 20 250 ms -0.00067 mV/LSB
16 SE Offset 5000 60-Hz Rejection ±25 LSB
17 Diff Offset 5000 60-Hz Rejection ±25 LSB
18 Gain 5000 60-Hz Rejection -0.167 mV/LSB
19 SE Offset 1000 60-Hz Rejection ±25 LSB
20 Diff Offset 1000 60-Hz Rejection ±25 LSB
21 Gain 1000 60-Hz Rejection -0.0333 mV/LSB
22 SE Offset 200 60-Hz Rejection ±30 LSB
23 Diff Offset 200 60-Hz Rejection ±30 LSB
Vue de la page 297